Related Categories:Electrical Wires
Fiberglass should be wrapped on the conductor tightly and evenly, for double fiberglass wrapped wire.

1.About product :

Main material:

CCC Chilean copper flat wire

Cu-CATH Cu+Ag≥99.95%

Executed Standard GB/T 467

Nominal size a

mm

Tolerance

mm

Nominal size b

mm

Tolerance

mm

Insulation size mm

Tolerance,%

a ≤1.70

-0.01+0.03

b ≤3.15

-0.01+0.03

 

 

1.70<a ≤3.15

-0.02+0.02

3.15<b ≤6.30

-0.03+0.03

 

 

3.15<a ≤4.50

-0.03+0.03

6.30<b ≤12.50

-0.03+0.05

 

 

4.50<a ≤7.10

-0.04+0.04

12.50<b ≤16.00

-0.05+0.07

 

 

 

Radius of round corner r and its tolerance range for cooper flat wire

Nominal dimension a,mm

Radius of round corner r,mm

Nominal dimension a,mm

Radius of round corner r,mm

Nominal value

Tolerance

Nominal value

Tolerance

a ≤1.00

a/2

 ±25%

2.24<a≤3.55

0.80

 ±25%

1.00<a≤1.60

0.50

3.55<a≤6.00

1.00

1.60<a≤2.24

0.65

6.00<a≤7.10

1.20

Some special dimension of wire can be produced on customer’s request.

2. Technical requirements

Appearance

The coat of immersed paint should be even, with same color, no defects that affect the property on surface.

The maximal outlined dimension

The maximal outlined dimension should not be more than the sum of the maximal dimension of conductor (Nominal dimension plus positive tolerance) and specified maximal thickness of insulation, if the maximal outlined dimension does not exceed the specified value, it is acceptable that the thickness of insulation exceed the related value.

Resistivity

Copper conductor: ≤      Ω•mm2/m

Elongation rate

The elongation rate should be more than or equal to the specified value in the following table.

Nominal dimension a,mm

Elongation rate,%

a≤2.50

30

a>2.50

32

Curvature

 According to the following table, after bending at wide edge and narrow edge on the round stick, insulation layer should have no crack and exposure of film.

Nominal dimension

Radius of round stick

2.00≤b≤8.00

10b

8.00<b≤16.00

15b

0.80<a≤5.60

10a

Resilience

According to the following table, after drawing, the insulation layer should not lose adhesion.

Nominal dimension,mm

Drawing,%

a<2.5

15

Breakthrough voltage

Bend the wire according to 4.8, take the test of breakthrough voltage by steel ball method, the breakthrough voltages of four trial samples should not be less than the specified value in the following table.

Nominal thickness of insulation,mm

Breakthrough voltage,V

Grade 2 GL1

1500

  

fiberglass wrapped enamel wrapped copper Magnetic wire